[back]      
LINTOLS

Concrete Lintols Load Vs Span Table
Lintol Type : 100mm x 140mm
Cover = 30mm
FCU = 50N/mm2
Overall
Clear Span
Safe Uniformly
Length (mm)
(mm)
Distributed Imposed load (kN)
450
150
34.8
600
300
23.2
750
750
17.3
900
600
13.8
1050
750
11.4
1200
900
9.7
1350
1050
9.4
1500
1200
9.0
1650
1350
10.8
1800
1500
10.8
1950
1650
10.8
2100
1800
10.7
2250
1950
12.4
2400
2100
11.0
2550
2250
9.6
2700
2400
8.6
2850
2550
7.6
Note for boot lintols use the table "Lintol type: 100x140mm"
for boot lintol that measures 100mm at the top and 140mm
in depth and for a lintol that measures 100mm at the top and
215mm in depth use the table "Lintol type: 100x215"
Lintol Type : 100mm x 215mm
Cover = 30mm
FCU = 50N/mm2
Overall
Clear Span
Safe Uniformly
Length (mm)
(mm)
Distributed Imposed load (kN)
450
N/A
N/A
600
150
99.8
750
300
59.8
900
450
42.7
1050
600
33.1
1200
750
27.0
1350
900
25.5
1500
1050
22.0
1650
1200
23.1
1800
1350
20.5
1950
1500
18.5
2100
1650
16.7
2250
1800
17.5
2400
1950
16.1
2550
2100
15.5
2700
2250
15.4
2850
2400
15.3
300
2550
15.3
3150
2700
15.2
3300
2850
15.1
3450
3000
15.1
3600
3150
15.0